Revise Surface plan per audit: near-vertical spec, calibration guards, shared settling, pure guidance mapping (Codex)
This commit is contained in:
+60
-26
@@ -1,6 +1,6 @@
|
||||
# Surface Level — Implementation Attack Plan
|
||||
|
||||
**Status:** Proposed; send to Claude for audit before implementation.
|
||||
**Status:** Audited; ready for implementation after this revision.
|
||||
**Scope:** Surface Level only. Do not change Angle, Edge, ruler, or billing in this stage.
|
||||
|
||||
## Outcome
|
||||
@@ -28,8 +28,13 @@ The user should be able to answer three questions at a glance or by sound:
|
||||
- Surface means the phone is intended to lie flat, screen-up, on the plane being
|
||||
measured. Its level-lock behavior is valid only in that geometry.
|
||||
- Numeric measurements are never hidden because the phone is steeply oriented.
|
||||
Outside the ideal Surface geometry, show the actual angle and a quiet placement
|
||||
Surface tilt magnitude remains authoritative from 0 to 180 degrees. Outside
|
||||
the ideal face-up geometry, show the actual magnitude and a quiet placement
|
||||
hint; suppress level-lock feedback rather than replacing the reading with `—`.
|
||||
- Above 80 degrees of tilt, de-emphasize/suppress Pitch and Roll because their
|
||||
off-axis parameterization becomes noisy near vertical. Above 90 degrees,
|
||||
identify the screen-down-side state rather than pretending the bullseye is a
|
||||
useful placement tool. The magnitude remains visible in both cases.
|
||||
- The central visualization is a bullseye vial. It has a finite visual range:
|
||||
beyond that range the bubble rests at the rim, while numeric information remains
|
||||
full-range and authoritative.
|
||||
@@ -42,20 +47,30 @@ The user should be able to answer three questions at a glance or by sound:
|
||||
|
||||
- Refactor Surface placement gating so it only controls the level-lock state,
|
||||
lock haptic, and geometry-specific guidance.
|
||||
- Keep primary angle, pitch, and roll visible at 0-90 degrees.
|
||||
- Add tests at flat, near level, 30 degrees, and near vertical proving numeric
|
||||
readings remain present and correct; verify invalid placement never locks.
|
||||
- Keep the primary tilt magnitude visible from 0-180 degrees. Keep Pitch and
|
||||
Roll visible only where their meaning is stable (below 80 degrees tilt).
|
||||
- Add tests at flat, near level, 30 degrees, 80 degrees, near vertical, and
|
||||
screen-down. Verify magnitude stays correct, off-axis values are suppressed
|
||||
in their ambiguous range, and invalid placement never locks.
|
||||
- Keep the existing lock tolerance semantics: a lock label states the tolerance
|
||||
rather than pretending any non-zero value is exactly flat.
|
||||
|
||||
### 2. Add the guided Surface calibration flow
|
||||
|
||||
- Add a Surface Calibration route from the Level header.
|
||||
- Explain that the phone may be calibrated on any firm, stable surface; the
|
||||
surface itself does not need to be level.
|
||||
- Step 1: settle, sample for a short stable window, capture.
|
||||
- Step 2: rotate the phone exactly 180 degrees in the same plane, settle, capture.
|
||||
- Reject/retry if readings indicate motion or inconsistent placement.
|
||||
- Explain that the phone may be calibrated on any firm, stable, *roughly level*
|
||||
surface; it need not be perfectly level. Warn and ask for a flatter surface
|
||||
when the measured tilt exceeds 5 degrees.
|
||||
- Capture the two samples from the uncalibrated sensor path. Never derive a new
|
||||
calibration from readings that an existing calibration has already corrected.
|
||||
- Step 1: settle, collect a 1.5-second stable window, capture.
|
||||
- Step 2: rotate the phone exactly 180 degrees in the same plane, settle, then
|
||||
collect and capture another 1.5-second stable window.
|
||||
- Use the shared settling detector: enter Settling above 1.0 degrees/second of
|
||||
two-axis plane movement; leave it only after movement is at or below 0.3
|
||||
degrees/second for 500 ms. Reject/retry windows that are not settled.
|
||||
- Reject/retry a derived calibration bias above 3 degrees as evidence that the
|
||||
device, setup, or turn was inconsistent. Suppress lock feedback during the flow.
|
||||
- Persist only the resulting Surface calibration; never alter Edge calibration.
|
||||
- State that the calibration applies to the current phone/case/contact setup.
|
||||
- On completion, show a concise success result and a way to clear/re-run it.
|
||||
@@ -67,10 +82,19 @@ The user should be able to answer three questions at a glance or by sound:
|
||||
- Glass, fluid, and meniscus effects must improve depth/readability; avoid a
|
||||
decorative or excessively glossy treatment.
|
||||
- Bubble target position derives directly from stable calibrated pitch/roll.
|
||||
- Bubble movement uses a critically damped animation toward that real target:
|
||||
no random drift, autonomous wobble, or animation that contradicts the number.
|
||||
- Derive bubble target, high/low instruction, and rise/run direction from one
|
||||
pure SurfaceGuidance function. Its hysteretic next-state input must prevent
|
||||
quadrant labels from flapping at an axis boundary. Use an edge label when the
|
||||
minor axis is under 25% of the dominant axis; otherwise use a corner label.
|
||||
- Bubble movement uses a critically damped spring (damping ratio >= 1) toward
|
||||
that real target: no overshoot, random drift, autonomous wobble, or animation
|
||||
that contradicts the number. Clamp the target to the vial's visual range before
|
||||
applying the spring so the bubble settles at the rim.
|
||||
- Etched rings are real visual calibration marks, not decoration: map them to
|
||||
explicit degree values (initially 1, 2, and 5 degrees) using the same pure
|
||||
measurement-to-position mapping as the bubble.
|
||||
- Respect disabled system animations and the app's reduced-motion preference by
|
||||
minimizing or removing the display spring.
|
||||
direct-positioning the deadbanded bubble value instead of running the spring.
|
||||
- Show a large total tilt beside/below the vial, then Pitch and Roll below it.
|
||||
- At level lock, use the restrained lime state and an explicit text label.
|
||||
|
||||
@@ -82,32 +106,42 @@ The user should be able to answer three questions at a glance or by sound:
|
||||
millimetres per metre and/or inches per foot based on the selected unit system.
|
||||
- Treat exact board/counter dimensions and calculated shim/foot height as a later
|
||||
Adjustment Assist feature, not a requirement of this stage.
|
||||
- When the reading is moving, show a subtle `Settling` state and defer strong
|
||||
correction guidance until the stable measurement is trustworthy.
|
||||
- Use the shared settling detector from calibration. When it is settling, show a
|
||||
subtle `Settling` state and defer strong correction guidance until the stable
|
||||
measurement is trustworthy.
|
||||
- Add a persisted units preference in core/settings for rise/run formatting;
|
||||
the Tools settings UI remains deferred.
|
||||
|
||||
### 5. Add optional hands-free Audio Level Assist
|
||||
|
||||
- Surface-only, off by default, explicitly user-enabled.
|
||||
- Use a soft sonar-like pulse with a gentle attack and naturally fading tail;
|
||||
never a harsh alarm or rapid smoke-detector cadence.
|
||||
- Silent while settling or materially outside the usable placement geometry.
|
||||
- Near level: occasional low-key proximity pulses.
|
||||
- Silent while the shared settling detector is active or materially outside the
|
||||
usable placement geometry.
|
||||
- Near level: occasional low-key proximity pulses with hysteresis between audio
|
||||
proximity bands, so band changes cannot chatter.
|
||||
- Locked: one distinct soft lock ping; optionally provide a sparse repeat-while-
|
||||
locked preference so a user adjusting a large plank can hear that it remains level.
|
||||
- Reuse the existing lock dwell/hysteresis/debounce so sound cannot chatter.
|
||||
- Respect media volume, audio focus, system sound settings, app lifecycle, and
|
||||
the user's Audio Assist preference.
|
||||
- Use SoundPool with `USAGE_ASSISTANCE_SONIFICATION`; mix with media rather than
|
||||
taking audio focus for intermittent pulses. Respect media volume, system sound
|
||||
settings, app lifecycle, and the user's Audio Assist preference. Release audio
|
||||
resources with the tool composable/flow collection.
|
||||
|
||||
## Surface acceptance criteria
|
||||
|
||||
- A stable phone on a known level plane achieves lock without repeated feedback.
|
||||
- A 180-degree calibration on a stable but non-level plane improves repeatability
|
||||
without zeroing that plane's real slope.
|
||||
- A screen-up phone at 30 and near 90 degrees still shows meaningful numbers;
|
||||
it does not falsely claim Surface lock.
|
||||
- Bubble direction agrees with Pitch/Roll and with the high/low instruction.
|
||||
- Bubble visual remains physically believable but never leads or disagrees with
|
||||
the stable numeric reading.
|
||||
- A 180-degree calibration from uncalibrated stable samples on a stable,
|
||||
roughly-level plane improves repeatability without zeroing that plane's real
|
||||
slope; inconsistent/moving captures are rejected.
|
||||
- A screen-up phone at 30, 80, near 90, and screen-down angles always shows a
|
||||
correct magnitude. Pitch/Roll are suppressed at their documented ambiguous
|
||||
range, and the Surface tool never falsely claims a lock.
|
||||
- Bubble direction, high/low instruction, and rise/run direction agree in all
|
||||
four quadrants through one pure, unit-tested guidance function.
|
||||
- Bubble position is a pure mapping of stable measurement plus a no-overshoot
|
||||
spring. Its etched rings match that mapping's documented degree marks.
|
||||
- Audio can guide a user to lock without viewing the screen and stays quiet when
|
||||
disabled, settling, backgrounded, or outside the Surface geometry.
|
||||
- Manual checks cover phone-with-case, phone-without-case, a firm tabletop, and
|
||||
|
||||
Reference in New Issue