Enclosure Axis Validation — 2026-08-16

The enclosure was tested with the battery end treated as the bottom of the reference orientation. The shared enclosure frame is +X right, +Y toward the top, and +Z toward the cover.

Capture integrity

  • 50,001 consecutive samples over 500.000 seconds
  • Effective sample rate: exactly 100 Hz
  • Timestamp interval: 10,000 us for every sample
  • Sequence gaps: 0
  • Axis-mapping mismatches between mapped and native columns: 0

The raw capture is captures/enclosure_axis_test.csv and is intentionally excluded from source control.

Accelerometer orientation results

Position Mean enclosure counts Expected dominant axis Result
Flat, cover up (+4, -5, +258) +Z Pass
Left edge down (+258, -3, +10) +X Pass
Right edge down (-260, -9, +16) -X Pass
Battery edge down (-3, +255, +11) +Y Pass
Top edge down (+5, -264, +15) -Y Pass
Cover side down (-7, -7, -234) -Z Pass

The paired-face results give an initial calibration estimate of:

offset_counts = (-1.30, -4.45, +12.20)
counts_per_g  = (258.90, 259.85, 245.70)

These values are recorded as candidates only; calibration is not yet applied in firmware.

Gyroscope rotation results

  • The deliberate X rotation was X-dominant in 1,261 dynamic samples, versus 44 Y-dominant and 35 Z-dominant samples.
  • The deliberate Z rotation was Z-dominant in all 1,008 dynamic samples. No X or Y sample crossed the same 500-count activity threshold.
  • Earlier side-to-side orientation changes were Y-dominant, confirming the remaining gyro axis.

The mounted sensor axes and the firmware's enclosure-frame mapping are consistent.